听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览NMR IN BIOMEDICINE期刊下所有文献
  • Robust hyperpolarized (13)C metabolic imaging with selective non-excitation of pyruvate (SNEP).

    abstract::In vivo metabolic imaging using hyperpolarized [1-(13)C]pyruvate provides localized biochemical information and is particularly useful in detecting early disease changes, as well as monitoring disease progression and treatment response. However, a major limitation of hyperpolarized magnetization is its unrecoverable d...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3346

    authors: Chen WC,Teo XQ,Lee MY,Radda GK,Lee P

    更新日期:2015-08-01 00:00:00

  • Direct dynamic measurement of intracellular and extracellular lactate in small-volume cell suspensions with (13)C hyperpolarised NMR.

    abstract::Hyperpolarised (HP) (13)C NMR allows enzymatic activity to be probed in real time in live biological systems. The use of in vitro models gives excellent control of the cellular environment, crucial in the understanding of enzyme kinetics. The increased conversion of pyruvate to lactate in cancer cells has been well st...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3341

    authors: Breukels V,Jansen KC,van Heijster FH,Capozzi A,van Bentum PJ,Schalken JA,Comment A,Scheenen TW

    更新日期:2015-08-01 00:00:00

  • A multi-Gaussian model for apparent diffusion coefficient histogram analysis of Wilms' tumour subtype and response to chemotherapy.

    abstract::Wilms' tumours (WTs) are large heterogeneous tumours, which typically consist of a mixture of histological cell types, together with regions of chemotherapy-induced regressive change and necrosis. The predominant cell type in a WT is assessed histologically following nephrectomy, and used to assess the tumour subtype ...

    journal_title:NMR in biomedicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/nbm.3337

    authors: Hales PW,Olsen ØE,Sebire NJ,Pritchard-Jones K,Clark CA

    更新日期:2015-08-01 00:00:00

  • Two-voxel spectroscopy with dynamic B0 shimming and flip angle adjustment at 7 T in the human motor cortex.

    abstract::The aim of this study was to acquire high-quality in vivo (1) H spectra concurrently from two voxels at ultra-high field (7 T) without specialized hardware. To this end, an acquisition scheme was developed in which first-order shims and flip angles are dynamically updated to acquire spectra from both of the brain's mo...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3328

    authors: Lemke C,Hess A,Clare S,Bachtiar V,Stagg C,Jezzard P,Emir U

    更新日期:2015-07-01 00:00:00

  • Feasibility and reproducibility of neurochemical profile quantification in the human hippocampus at 3 T.

    abstract::Hippocampal dysfunction is known to be associated with several neurological and neuropsychiatric disorders such as Alzheimer's disease, epilepsy, schizophrenia and depression; therefore, there has been significant clinical interest in studying hippocampal neurochemistry. However, the hippocampus is a challenging regio...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3309

    authors: Bednařík P,Moheet A,Deelchand DK,Emir UE,Eberly LE,Bareš M,Seaquist ER,Öz G

    更新日期:2015-06-01 00:00:00

  • Continuous-wave saturation considerations for efficient xenon depolarization.

    abstract::The combination of hyperpolarized Xe with chemical exchange saturation transfer (Hyper-CEST) is a powerful NMR technique to detect highly dilute concentrations of Xe binding sites using RF saturation pulses. Crucially, that combination of saturation pulse strength and duration that generates the maximal Hyper-CEST eff...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3307

    authors: Kunth M,Witte C,Schröder L

    更新日期:2015-06-01 00:00:00

  • Interventional MRI-guided local delivery of agents into swine bile duct walls using MR-compatible needle-integrated balloon catheter system.

    abstract::The purpose of this study was to investigate the feasibility of interventional MRI-guided local agent delivery into pig common bile duct (CBD) walls using a newly designed MR-compatible, needle-integrated balloon catheter system. We first designed a needle-integrated balloon catheter system that comprised of a 22 G MR...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3308

    authors: Zhang F,Bai Z,Shi Y,Wang J,Li Y,Yang X

    更新日期:2015-06-01 00:00:00

  • Imaging chemical exchange saturation transfer (CEST) effects following tumor-selective acidification using lonidamine.

    abstract::Increased lactate production through glycolysis in aerobic conditions is a hallmark of cancer. Some anticancer drugs have been designed to exploit elevated glycolysis in cancer cells. For example, lonidamine (LND) inhibits lactate transport, leading to intracellular acidification in cancer cells. Chemical exchange sat...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3287

    authors: McVicar N,Li AX,Meakin SO,Bartha R

    更新日期:2015-05-01 00:00:00

  • Hemispheric asymmetry in cerebrovascular reactivity of the human primary motor cortex: an in vivo study at 7 T.

    abstract::Current functional MRI (fMRI) approaches assess underlying neuronal activity through monitoring the related local variations in cerebral blood oxygenation, blood volume and blood flow. This vascular response is likely to vary across brain regions and across individuals, depending on the composition of the local vascul...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3282

    authors: Driver ID,Andoh J,Blockley NP,Francis ST,Gowland PA,Paus T

    更新日期:2015-05-01 00:00:00

  • 4D MRI of polycystic kidneys from rapamycin-treated Glis3-deficient mice.

    abstract::Polycystic kidney disease (PKD) is a life-threatening disease that leads to a grotesque enlargement of the kidney and significant loss of function. Several imaging studies with MRI have demonstrated that cyst size in polycystic kidneys can determine disease severity and progression. In the present study, we found that...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3281

    authors: Xie L,Qi Y,Subashi E,Liao G,Miller-DeGraff L,Jetten AM,Johnson GA

    更新日期:2015-05-01 00:00:00

  • Knee MRI under varying flexion angles utilizing a flexible flat cable antenna.

    abstract::The aim of this study is to fabricate and test a novel flexible flat cable antenna (FFCA) for MRI of the knee at different flexion angles. The FFCA was made of a flat cable, a tuning/matching circuit and a signal transmission line. To test its feasibility and validity, in vitro and in vivo experiments were carried out...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3264

    authors: Jia F,Yuan H,Zhou D,Zhang J,Wang X,Fang J

    更新日期:2015-04-01 00:00:00

  • Multi-center reproducibility of neurochemical profiles in the human brain at 7 T.

    abstract::The purpose of this work was to harmonize data acquisition and post-processing of single voxel proton MRS ((1) H-MRS) at 7 T, and to determine metabolite concentrations and the accuracy and reproducibility of metabolite levels in the adult human brain. This study was performed in compliance with local institutional hu...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,多中心研究

    doi:10.1002/nbm.3252

    authors: van de Bank BL,Emir UE,Boer VO,van Asten JJ,Maas MC,Wijnen JP,Kan HE,Oz G,Klomp DW,Scheenen TW

    更新日期:2015-03-01 00:00:00

  • Transcranial direct current stimulation promotes the mobility of engrafted NSCs in the rat brain.

    abstract::Transcranial direct current stimulation (tDCS) is used in numerous clinical studies and considered an effective and versatile add-on therapy in neurorehabilitation. To date, however, the underlying neurobiological mechanisms remain elusive. In a rat model of tDCS, we recently observed a polarity-dependent accumulation...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3244

    authors: Keuters MH,Aswendt M,Tennstaedt A,Wiedermann D,Pikhovych A,Rotthues S,Fink GR,Schroeter M,Hoehn M,Rueger MA

    更新日期:2015-02-01 00:00:00

  • Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects.

    abstract::Chemical exchange saturation transfer (CEST) potentially provides the ability to detect small solute pools through indirect measurements of attenuated water signals. However, CEST effects may be diluted by various competing effects, such as non-specific magnetization transfer (MT) and asymmetric MT effects, water long...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3243

    authors: Li H,Zu Z,Zaiss M,Khan IS,Singer RJ,Gochberg DF,Bachert P,Gore JC,Xu J

    更新日期:2015-02-01 00:00:00

  • FID navigator-based MR thermometry method to monitor small temperature changes in the brain of ventilated animals.

    abstract::An MR thermometry method is proposed for measuring in vivo small temperature changes engendered by external RF heat sources. The method relies on reproducible and stable respiration and therefore currently applies to ventilated animals whose breathing is carefully controlled. It first consists in characterizing the st...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3232

    authors: Boulant N,Bottlaender M,Uhrig L,Giacomini E,Luong M,Amadon A,Massire A,Larrat B,Vignaud A

    更新日期:2015-01-01 00:00:00

  • Lung ventilation volumetry with same-breath acquisition of hyperpolarized gas and proton MRI.

    abstract::The purpose of this work was to assess the reproducibility of percentage of ventilated lung volume (PV) measured from hyperpolarized (HP) (3)He and (1)H anatomical images acquired in the same breath-hold when compared with PV measured from (3)He and (1)H images from separate breath-holds. Volumetric (3)He ventilation ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3187

    authors: Horn FC,Tahir BA,Stewart NJ,Collier GJ,Norquay G,Leung G,Ireland RH,Parra-Robles J,Marshall H,Wild JM

    更新日期:2014-12-01 00:00:00

  • MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements.

    abstract::Both post-contrast myocardial T1 and extracellular volume (ECV) have been reported to be associated with diffuse interstitial fibrosis. Recently, the cardiovascular magnetic resonance (CMR) field is recognizing that post-contrast myocardial T1 is sensitive to several confounders and migrating towards ECV as a measure ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3221

    authors: Hong K,Kim D

    更新日期:2014-11-01 00:00:00

  • Cardiac lipid levels show diurnal changes and long-term variations in healthy human subjects.

    abstract::(1) H-MRS is regularly applied to determine lipid content in ectopic tissue - mostly skeletal muscle and liver - to investigate physiological and/or pathologic conditions, e.g. insulin resistance. Technical developments also allow non-invasive in vivo assessment of cardiac lipids; however, basic data about methodologi...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3186

    authors: Ith M,Stettler C,Xu J,Boesch C,Kreis R

    更新日期:2014-11-01 00:00:00

  • A pilot validation of multi-echo based echo-planar correlated spectroscopic imaging in human calf muscles.

    abstract::A current limitation of MR spectroscopic imaging of multiple skeletal muscles is prolonged scan duration. A significant reduction in the total scan duration using the echo-planar correlated spectroscopic imaging (EP-COSI) sequence was accomplished using two bipolar readout trains with different phase-encoded echoes fo...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3171

    authors: Furuyama JK,Nagarajan R,Roberts CK,Lee CC,Hahn TJ,Thomas MA

    更新日期:2014-10-01 00:00:00

  • In vivo 1H MRS of human gallbladder bile at 3 T in one and two dimensions: detection and quantification of major biliary lipids.

    abstract::In vitro (1)H MRS of human bile has shown potential in the diagnosis of various hepatopancreatobiliary (HPB) diseases. Previously, in vivo (1)H MRS of human bile in gallbladder using a 1.5 T scanner demonstrated the possibility of quantification of choline-containing phospholipids (chol-PLs). However, other lipid comp...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3173

    authors: Mohajeri S,Ijare OB,Bezabeh T,King SB,Thomas MA,Minuk G,Lipschitz J,Kirkpatrick I,Smith M,Smith IC

    更新日期:2014-10-01 00:00:00

  • Increased sensitivity of 31P MRSI using direct detection integrated with multi-echo polarization transfer (DIMEPT).

    abstract::Here, we show that the sensitivity of (31)P MRSI of (31)P spins J-coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi-echo polarization transfer (DIMEPT), multiple signals from polarization transf...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3183

    authors: van der Kemp WJ,Boer VO,Luijten PR,Klomp DW

    更新日期:2014-10-01 00:00:00

  • Discrimination between glioblastoma multiforme and solitary metastasis using morphological features derived from the p:q tensor decomposition of diffusion tensor imaging.

    abstract::The management and treatment of high-grade glioblastoma multiforme (GBM) and solitary metastasis (MET) are very different and influence the prognosis and subsequent clinical outcomes. In the case of a solitary MET, diagnosis using conventional radiology can be equivocal. Currently, a definitive diagnosis is based on h...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3163

    authors: Yang G,Jones TL,Barrick TR,Howe FA

    更新日期:2014-09-01 00:00:00

  • Glioma grading using apparent diffusion coefficient map: application of histogram analysis based on automatic segmentation.

    abstract::The accurate diagnosis of glioma subtypes is critical for appropriate treatment, but conventional histopathologic diagnosis often exhibits significant intra-observer variability and sampling error. The aim of this study was to investigate whether histogram analysis using an automatically segmented region of interest (...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3153

    authors: Lee J,Choi SH,Kim JH,Sohn CH,Lee S,Jeong J

    更新日期:2014-09-01 00:00:00

  • Metabolic spectroscopy of inflammation in a bleomycin-induced lung injury model using hyperpolarized 1-(13) C pyruvate.

    abstract::Metabolic activity in the lung is known to change in response to external insults, inflammation, and cancer. We report measurements of metabolism in the isolated, perfused rat lung of healthy controls and in diseased lungs undergoing acute inflammation using hyperpolarized 1-(13) C-labeled pyruvate. The overall appare...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3139

    authors: Shaghaghi H,Kadlecek S,Deshpande C,Siddiqui S,Martinez D,Pourfathi M,Hamedani H,Ishii M,Profka H,Rizi R

    更新日期:2014-08-01 00:00:00

  • A system for automated noise parameter measurements on MR preamplifiers and application to high B(0) fields.

    abstract::A noise figure and noise parameter measurement system was developed that consists of a combination spectrum and network analyzer, preamplifier, programmable power supply, noise source, tuning board, and desktop computer. The system uses the Y-factor method for noise figure calculation and allows calibrations to correc...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3138

    authors: Lagore RL,Roberts BR,Possanzini C,Saylor C,Fallone BG,De Zanche N

    更新日期:2014-08-01 00:00:00

  • Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T.

    abstract::The increased magnetic susceptibility effects at higher magnetic fields increase the demands for shimming of the B0 field for in vivo MRI and MRS. Both static and dynamic techniques have been developed to compensate for susceptibility-induced field inhomogeneities. In this study, we investigate the impact of and need ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3096

    authors: Boer VO,Luttje MP,Luijten PR,Klomp DW

    更新日期:2014-06-01 00:00:00

  • Signal-to-noise ratio of a mouse brain (13) C CryoProbe™ system in comparison with room temperature coils: spectroscopic phantom and in vivo results.

    abstract::MRI and MRS in small rodents demand very high sensitivity. Cryogenic transmit/receive radiofrequency probes (CryoProbes) designed for (1) H MRI of mouse brain provide an attractive option for increasing the performance of small-animal MR systems. As the Larmor frequency of (13) C nuclei is four times lower than that f...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3110

    authors: Sack M,Wetterling F,Sartorius A,Ende G,Weber-Fahr W

    更新日期:2014-06-01 00:00:00

  • Time-dependent diffusion in skeletal muscle with the random permeable barrier model (RPBM): application to normal controls and chronic exertional compartment syndrome patients.

    abstract::The purpose of this work was to carry out diffusion tensor imaging (DTI) at multiple diffusion times Td in skeletal muscle in normal subjects and chronic exertional compartment syndrome (CECS) patients and analyze the data with the random permeable barrier model (RPBM) for biophysical specificity. Using an institution...

    journal_title:NMR in biomedicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/nbm.3087

    authors: Sigmund EE,Novikov DS,Sui D,Ukpebor O,Baete S,Babb JS,Liu K,Feiweier T,Kwon J,McGorty K,Bencardino J,Fieremans E

    更新日期:2014-05-01 00:00:00

  • The interaction between apparent diffusion coefficients and transverse relaxation rates of human brain metabolites and water studied by diffusion-weighted spectroscopy at 7 T.

    abstract::The dependence of apparent diffusion coefficients (ADCs) of molecules in biological tissues on an acquisition-specific timescale is a powerful mechanism for studying tissue microstructure. Unlike water, metabolites are confined mainly to intracellular compartments, thus providing higher specificity to tissue microstru...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3085

    authors: Branzoli F,Ercan E,Webb A,Ronen I

    更新日期:2014-05-01 00:00:00

  • Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI.

    abstract::Chemical exchange saturation transfer (CEST)-derived, pH-weighted, amide proton transfer (APT) MRI has shown promise in animal studies for the prediction of infarction risk in ischemic tissue. Here, APT MRI was translated to patients with acute stroke (1-24 h post-symptom onset), and assessments of APT contrast, perfu...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3048

    authors: Tietze A,Blicher J,Mikkelsen IK,Østergaard L,Strother MK,Smith SA,Donahue MJ

    更新日期:2014-02-01 00:00:00

  • Integrated Laplacian-based phase unwrapping and background phase removal for quantitative susceptibility mapping.

    abstract::Quantitative susceptibility mapping (QSM) is a recently developed MRI technique that provides a quantitative measure of tissue magnetic susceptibility. To compute tissue magnetic susceptibilities based on gradient echoes, QSM requires reliable unwrapping of the measured phase images and removal of contributions caused...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3056

    authors: Li W,Avram AV,Wu B,Xiao X,Liu C

    更新日期:2014-02-01 00:00:00

  • Mapping of prostate cancer by 1H MRSI.

    abstract::In many studies, it has been demonstrated that (1)H MRSI of the human prostate has great potential to aid prostate cancer management, e.g. in the detection and localisation of cancer foci in the prostate or in the assessment of its aggressiveness. It is particularly powerful in combination with T2 -weighted MRI. Never...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.2973

    authors: Kobus T,Wright AJ,Scheenen TW,Heerschap A

    更新日期:2014-01-01 00:00:00

  • Q-ball imaging with PROPELLER EPI acquisition.

    abstract::Q-ball imaging (QBI) is an imaging technique that is capable of resolving intravoxel fiber crossings; however, the signal readout based on echo-planar imaging (EPI) introduces geometric distortions in the presence of susceptibility gradients. This study proposes an imaging technique that reduces susceptibility distort...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3009

    authors: Chou MC,Huang TY,Chung HW,Hsieh TJ,Chang HC,Chen CY

    更新日期:2013-12-01 00:00:00

  • Effect of taxane-based neoadjuvant chemotherapy on fibroglandular tissue volume and percent breast density in the contralateral normal breast evaluated by 3T MR.

    abstract::The aim of this study was to evaluate the change of breast density in the normal breast of patients receiving neoadjuvant chemotherapy (NAC). Forty-four breast cancer patients were studied. MRI acquisition was performed before treatment (baseline), and 4 and 12 weeks after treatment. A computer-algorithm-based program...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3006

    authors: Chen JH,Pan WF,Kao J,Lu J,Chen LK,Kuo CC,Chang CK,Chen WP,McLaren CE,Bahri S,Mehta RS,Su MY

    更新日期:2013-12-01 00:00:00

  • MR imaging of protein folding in vitro employing nuclear-Overhauser-mediated saturation transfer.

    abstract::MR Z-spectroscopy allows enhanced imaging contrast on the basis of saturation transfer between the proton pools of cellular compounds and water, occurring via chemical exchange (chemical exchange saturation transfer, CEST) or dipole-dipole coupling (nuclear Overhauser effect, NOE). In previous studies, signals observe...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3021

    authors: Zaiss M,Kunz P,Goerke S,Radbruch A,Bachert P

    更新日期:2013-12-01 00:00:00

  • Quantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination.

    abstract::The cuprizone mouse model of demyelination was used to investigate the influence that white matter changes have on different magnetic resonance imaging results. In vivo T2 -weighted and magnetization transfer images (MTIs) were acquired weekly in control (n = 5) and cuprizone-fed (n = 5) mice, with significant increas...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2992

    authors: Thiessen JD,Zhang Y,Zhang H,Wang L,Buist R,Del Bigio MR,Kong J,Li XM,Martin M

    更新日期:2013-11-01 00:00:00

  • DTI of human skeletal muscle: the effects of diffusion encoding parameters, signal-to-noise ratio and T2 on tensor indices and fiber tracts.

    abstract::In this study, we have performed simulations to address the effects of diffusion encoding parameters, signal-to-noise ratio (SNR) and T2 on skeletal muscle diffusion tensor indices and fiber tracts. Where appropriate, simulations were corroborated and validated by in vivo diffusion tensor imaging (DTI) of human skelet...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2959

    authors: Froeling M,Nederveen AJ,Nicolay K,Strijkers GJ

    更新日期:2013-11-01 00:00:00

  • Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

    abstract::Transceiver surface coil arrays improve transmit performance (B1/√kW) and B1 homogeneity for head imaging up to 9.4 T. To further improve reception performance and parallel imaging, the number of array elements must be increased with a corresponding decrease in their size. With a large number of small interacting ante...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2989

    authors: Avdievich NI,Pan JW,Hetherington HP

    更新日期:2013-11-01 00:00:00

  • Amide proton transfer imaging of the human breast at 7T: development and reproducibility.

    abstract::Chemical exchange saturation transfer (CEST) can offer information about protons associated with mobile proteins through the amide proton transfer (APT) effect, which has been shown to discriminate tumor from healthy tissue and, more recently, has been suggested as a prognosticator of response to therapy. Despite this...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2947

    authors: Klomp DW,Dula AN,Arlinghaus LR,Italiaander M,Dortch RD,Zu Z,Williams JM,Gochberg DF,Luijten PR,Gore JC,Yankeelov TE,Smith SA

    更新日期:2013-10-01 00:00:00

  • 31P NMR relaxation of cortical bone mineral at multiple magnetic field strengths and levels of demineralization.

    abstract::Recent work has shown that solid-state (1) H and (31) P MRI can provide detailed insight into bone matrix and mineral properties, thereby potentially enabling differentiation of osteoporosis from osteomalacia. However, (31) P MRI of bone mineral is hampered by unfavorable relaxation properties. Hence, accurate knowled...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2930

    authors: Seifert AC,Wright AC,Wehrli SL,Ong HH,Li C,Wehrli FW

    更新日期:2013-09-01 00:00:00

295 条记录 3/8 页 « 12345678 »